Replacing the UV Lamp
When to replace the UV Lamp
For maximum UV sanitization effect, replace the UV lamp after 13,000 hours or 18 months of operation.
Use Precaution
Wear proper eye and skin protection for servicing and cleaning glass components.
Exposure to UV light from this device is harmful to skin and eyes.
Do not attempt to remove the UV lamp while it is lit.
How to Remove UV Lamp
- Make sure the unit is disconnected from power and the lamp has cooled before performing maintenance.
- Disconnect the power connector between the UV lamp and wire harness.
- Gently pull on the UV lamp wires until the top of the UV lamp is out of the UV lamp retainer.
- Grasp the white ceramic end of the UV lamp and pull until it is fully removed.
- UV Lamp CONTAINS MERCURY (Hg). Dispose of properly, in accordance with disposal laws. See: www.lamprecycle.org
Installing new UV Lamp
Make sure to only handle the new UV lamp by the ceramic ends.
Carefully push the UV lamp into the UV lamp retainer until the top of the UV lamp is past the tabs on the UV lamp retainer.
Reconnect the UV lamp power connector to the wire harness.